SY-G080 Medical clinical digital double-channels syringe pump
Brand Name: Sunnymed
Model Number: SY-G080
Packaging Details: Carton or wooden case, standard export packing
Delivery Detail: In 10 days after payment received
Port: Guangzhou
MOQ:1 set
Brand Name: Sunnymed
Model Number: SY-G080
Packaging Details: Carton or wooden case, standard export packing
Delivery Detail: In 10 days after payment received
Port: Guangzhou
MOQ:1 set
Features and Functions:
1.Double-channels(multi-channels), sub-rate injection.
2.Four kinds of injection modes: Rate mode, Time mode, Body Weight mode, link mode.
3.Innovative design of outer appearance gives a strong sense of science and technology.
4.Double CPU makes the process of injection safer and more reliable.
5. The use of TFT color LCD makes the screen display more remarkable.
6. Digital menu, easy operation; functions fully meet the clinical demand.
7.Integrative pump device makes more smooth operation and easier installation and maintenance.
8.Brand-new STM32 ARM-Cortex M3 platform, optimized circuit design, operation rate more faster and stable.
9. Ample and user-friendly indicator information; accurate and complete alarm information to ensure safe injection.
10. Unique wireless infusion supervision function, achieving accurate infusion
and synchronization infusion supervision to patients.
Technical Parameters :
| Max. injection rate | 1500ml/h(Different injectors have
different maximum rate.) |
Accumulated volume | 0.1ml~999.9ml |
| Max. size of outer shell | 320 mm×200 mm×110 mm
(length×width×height) |
Injection accuracy | ±3% ( up to +1%
after calibration.) |
| Applicable injectors | 5, 10, 20, 30, 50ml | Injection increment | 0.1ml/h |
| Battery | AC 100~240V,50/60Hz | Volume limit | 0.1ml~999.9ml |
| Battery recharge | Rechargeable Lithium Polymer battery,
7.4V, 1600mA |
Classification | ClassⅡ, Type BF |
| Max. power consumption | Single-channel works for continuous 5 hours at the
rate of 25ml/h after fully recharged; double-channels works for continuous 3 hours at the rate of 25ml/h after fully recharged. |
||
| Range of flow rate | 5ml injector: 0.1ml/h~100ml/h 10ml injector:0.1ml/h~200ml/h
20ml injector:0.1ml/h~400ml/h 30ml injector:0.1ml/h~600ml/h 50ml injector:0.1ml/h~1500ml/h |
||
| Bolus rate | 5ml injector: 100ml/h 10ml injector:200ml/h
20ml injector:400ml/h 30ml injector:400~600ml/h (adjustable) 50ml injector:400~1500ml/h(adjustable) |
||
| Alarm information | Near completion, completion, OCCL., injector off, low voltage,
No AC Power supply, communication error, link abnormal, pump stuck, reading error of the parameters, etc.
|
||
| Mode selection | 1. Rate mode 2. Time mode 3. Body Weight mode 4. Link mode | ||
| Rate mode | Rate:0.1ml/h~1500.0ml/h
(Max. value depends on injector specification) |
||
| Time mode | Volume:0.1ml~999.9ml Time:1min.~2000 min. | ||
| Body Weight mode | Weight:0.1kg~300.0kg drug:0.1mg~999.9mg
volume:0.1ml~999.9ml dose:0.1~1500.0 (restricted to unit, drug, solution, weight and injector) Unit:mg/kg/h, ug/kg/min |
||
| OCCL. value | 40Kpa~160Kpa,display the voltage status and the pressure value. | ||
| KVO rate | Adjustable range:0.1ml/h~5.0ml/h
(adjustable: 0.1ml/h per each segment, press “0” to cancel KVO function.) |
||